TRANSISITON _FROM_ETMX lockloss troublshooting

Sheila, Camilla.

After this morning's windy lockloss from TRANSISITON _FROM_ETMX, we continued previous 77366 troubleshooting.

Sheila manually stepped though TRANSISITON _FROM_ETMX:

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 15:40, Tuesday 07 May 2024 (77698)

[RyanS, TJ, Jenne]

We've had 2 locklosses today that seem to be about when that MadHatter Darm FM2 gets turned off.  But, since Sheila and Camilla moved the filter turning off, now the locklosses are happening a little later.

As Camilla points out, the ramptime of that filter inside Foton is very short.  I've increased it to 3 seconds and we're about to give it a try (since I don't have a better plan to try right now).  Something we haven't seen (since we're already locked right now) is whether increasing the ramp of that filter inside Foton causes trouble for the engagement of that filter, in DARM_OFFSET.

EDIT: Indeed we made it through the turning-off of the MadHatter filter with this 3 second ramp time (rather than the previous 0.1 sec ramp).  I am hopeful that it won't matter for the turning-on of the filter, since that happens in a quite stable part of the locking sequence.  But, we'll just have to see over the next few lock acquisitions.

Also EDIT: If we are unable to relock with this ramp time, attached is a screenshot of the previous ramp time, that we should revert to.

Images attached to this comment
jenne.driggers@LIGO.ORG - 11:47, Wednesday 08 May 2024 (77716)

We've now relocked twice with the longer ramp time in the MadHatter filter in place for the turn-on and turn-off actions of that filter, so it seems fine to leave in place. 