H1 Out of Observing for SQZ Fixes

H1 was out of observing from 14:53 to 15:36 UTC to fix some issues with the SQZ system as we were seeing last night.

After Sheila adjusted the fiber polarization (alog77754), I reverted Corey's changes to the SQZ Guardians' nominal states (listed in his alog77740), then optimized the SQZ angle by running SQZ_MANAGER through 'SCAN_ALIGNMENT_FDS' and 'SCAN_SQZANG,' increasing BNS range by ~10Mpc.

Comments related to this report
ryan.short@LIGO.ORG - 10:17, Friday 10 May 2024 (77761)

After optimizing the SQZ angle, I accepted SDF diffs for alignment changes of ZM4 and ZM6 (screenshot attached).