Summary of the report:
- The duty cycle for this week was 61.6%.
- Most of the locklosses were due to earthquake, wind or commissioning.
- The average range started with ~150 Mpc and increased to ~155 Mpc by the end of the week. It reached to ~160 Mpc on Wednesday.
- There was nothing unusual in the glitchgram. Sometimes the glitchrates increased, mostly the reason was windy conditions.
- There are some high (~500 & ~1000 Hz) noise lines in the h(t) spectrogram during the whole week. At the end of the week, some high (>1000 Hz) noises were visible after H1 came back to observing after a lockloss.
- There were several noises in the EX and EY accoustics during the beginning of the week. The noise reduced significantly by the end of the week.
- Hveto: There are 10 new channels that appeared this week (details in the daily report).
- Fscan: All plots have appeared except Saturday. The line counts ranged between 600 to 850. They did not cross the threshold any day.
Full link to the report: Report.