sheila.dwyer@LIGO.ORG - posted 13:59, Monday 13 May 2024 - last comment - 14:21, Monday 13 May 2024(77812)
angle to length decoupling may need retuning

It looks like CHARD P coherence with DARM is rather high, this might be contributing to the low range at the moment.

I've added this dtt template to userapps/isc/h1/templates/DARM_coherence_check.xml, so that operators can use it to check coherences with LSC, ASC, and jitter any time that the range is low. 

 

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 14:21, Monday 13 May 2024 (77813)

Adding to this an example of using the sqz blrms template to look at the level of the 350 Hz (yellow BLRMS 3 trace) and 1.7kHz (purple BLRMS 6 trace) now compared to a time of good range.

It looks like Ryan's running SCAN_ALIGNMENT and SCAN_SQZANG earlier today did help improve the squeezing level.

This template can be found in userapps/sqz/h1/Templates/ndscope/sqz_blrms_range_2days.yaml  or from the SQZ_OVERVIEW medm screen.