Displaying report 1-1 of 1.
Reports until 08:33, Thursday 16 May 2024
H1 ISC (ISC, PEM)
corey.gray@LIGO.ORG - posted 08:33, Thursday 16 May 2024 (77866)
Ran Low Range DTT Template This Morning During H1's Range Drop Due To Something Seismic

With our 3-hr range drop earlier this morning which is coincident mainly with seismic from 3-10Hz in corner (smaller at end stations & for 10-30Hz band), got some practice running new "Low-Range Check" dtt template (wiki link) with a time of 1317utc (617PDT).  Notables on it is the noise increase seen in the DARM spectrum from 18-70Hz; can also see slight jitter increase for WFS B Yaw from 7-13Hz.

Template Note:  Sheila mentioned for Input tab/NDS2, we can leave Epoch Start Time as is, and for the Stop Time you can go back 10min (I'll  update the wiki to show this note).

Images attached to this report
Displaying report 1-1 of 1.