TITLE: 05/19 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Oli
SHIFT SUMMARY:
Lockloss @ 2:37 UTC
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1400121463
I'm fairly confident that a strong wind gust may have unlocked us.
5.5 Mag Earthquake from the top of the world: https://earthquake.usgs.gov/earthquakes/eventpage/us6000mzkf/
I'm Having a reall dificult time getting DRMI & PRMI to lock for some reason. very similar to Ryan's Alog:
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=77906
Touched the beam splitter a nudge in a few directions to try and lock PRMI.
Check mich fringes is also saying the Beam splitter too far misaligned!
This seems like just a bad alignment and may be related to the fact that the Last Initial Alignment, was done during an earthquake.
GRB-Short E484987
Took alignment back to GPS time: 1400035904 ( the tail end of Initial Alignment before the last good long lock stretch.)
Can now certainly rule out bad alignment. Took PRMI-MICH to 2.6 and the PRMI lock lasts a little longer but still ultimately doesnt stay locked.
I'm now trying the PRMI-PRCL at 4 like Ryan suggested. As I too am seeing the PRMI 20 Hz wiggle Ryan was speaking about.
GRB-Short E484996
I tried to Manual ISC lock through PRMI to test diffent settings so see if they would actually lock PRMI for any longer. I cannot keep PRMI Locked for more than 3 seconds.
Trending PRM Slide values I see that pitch is higher by 11ish and Yaw is higher by 3 ish since the last long lock.
The way I have been editing lsc params is clicking the edit button on ISC_DRMI guardian. This for me opens Pycharm, which also opens lscparams file.
I have been editing line 191and line 193 and the load the Guardian.
20 hz wiggle became a 30 hz wiggle.
When I could get PRMI to Lock the lock would immdiately lose lock right afterwards.