TITLE: 05/19 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 8mph Gusts, 4mph 5min avg
Primary useism: 0.04 μm/s
Secondary useism: 0.09 μm/s
QUICK SUMMARY:
IFO is now at Laser Noise Suppression and going up! Ryan was able to get H1 the IFO past PRMI.
If we lose lock and get back into PRMI, 2 OLG measurements to take :
/opt/rtcds/userapps/release/lsc/h1/templates/PRCL/PRCL/PRCL_OLG_PRMI.xml
&
/opt/rtcds/userapps/release/lsc/h1/templates/MICH/MICH/MICH_OLG_PRMI.xml
and for DRMI :
/opt/rtcds/userapps/release/lsc/h1/templates/PRCL/PRCL/PRCL_OLG_DRMI.xml
&
/opt/rtcds/userapps/release/lsc/h1/templates/MICH/MICH/MICH_OLG_DRMI.xml
Hopefully we wont have to relock at all.
Ryans Changed made to the Gains in lcsparams.py and Timers in ISC_DRMI.py have Not been Reverted.
SDF diff that had to be accepted to get into OBSERVING:
H1:SYS-MOTION_C_PICO_A_CURRENT_ENABLE
This SDF Diff was reverted: H1:SYS-MOTION_C_PICO_A_CURRENT_ENABLE
I will be watching H1:LSC-POP_A_LF_NORM_MON to see if we thermalize a little closer to what we saw a week about 10 days ago , note the Y cursur at 515.119 counts.
H1:LSC-POP_A_LF_NORM_MON as of right now with the same cursur location from 10 days prior.
I ran a SCAN_ALIGNMENT_FDS then a SCAN_SQZANG.
Before the SQZ SCAN and after the SQZ SCAN are on either side of the T cursor