TITLE: 05/26 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 12mph Gusts, 8mph 5min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.07 μm/s
QUICK SUMMARY:
Relocking notes:
Mysterious lockloss at Prep_TR_CARM after a suspicious HAM6 saturation.
Some investigations show me a possible CPS glitch on HAM 6 now. tagging SEI. See screenshot.
ALSX went through Increase flashes then had a fault for PLL & PDH, going to green arms manual.
I unlocked ALSX and requested Lock_slow_no_WFS. this did not fix the issue, but it did eventually start staying locked for longer.
so I sent it to Locking ALS to see if I'd get another lockloss. So far its going well.
made it to NLN at 17:21 UTC.
17:24 UTC Observing reached.