camilla.compton@LIGO.ORG - posted 12:15, Wednesday 29 May 2024 - last comment - 12:15, Wednesday 29 May 2024(78115)
Looking at SQZ and IFO alignment and throughput on AS_C

Sheila, Camilla 

As we were re-locking before commissioning time, we paused with ISC_LOCK in IDLE to check the alignment of SQZ and the IFO on AS_C.
Changed SQZ alignment, unsure if better or worse until we lock.

Checking SQZ:

Checking IFO:

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 12:11, Wednesday 29 May 2024 (78120)

Naoki, Sheila, Camilla

We tried this alignment and the middle, mainly changing pitch alignment. Both of these were considerable worse. We went back to yesterdays alignment, hand adjusted ZM4/6 in ASQZ then ran SCAN_SQZALIGN. Sdf's attached accepted.

Back to 4.5dB of SQZ above 1kHz and our reference 100-100Hz. SQZ seems to still be injecting low frequency noise. 

Kappa_C is 0.5% better in this new SRC spot, plot attached.