9.5 Hz comb triplet likely started early Sept 2021 amid PSL upgrade work

Ansel and Sheila following up on 77990. This work relates to the 9.5 Hz comb triplet .

Channels involved

(Thanks to Sheila for guidance on channels and times here!)

Comb history

With this information in hand, it was possible to track the 9.5 Hz combs back to a likely start date on or near Sept 2, 2021. Details:

Checking the alogs around that time, there was quite a bit of PSL upgrade work ongoing, as summarized in 59832.

This work is ongoing; as before, details and work-in-progress notes can be found on gitlab. Anamaria and Matt H have supplied a number of times to look at LLO data (recall that these combs have counterparts at LLO), particularly for dark spectra of the ISS PDs. This is next on the to-do list.

What about the 11.9 Hz comb mentioned in the previous alog?

It's also in a lot of these channels! However, unlike the 9.5 Hz, I don't see a notable change point in early September. This is not really surprising, since the 11.9 Hz comb was noted in O3. I'm focusing on the 9.5 Hz combs first, which are more pervasive, but keeping an eye out for more 11.9 Hz clues along the way.

Anybody interested in looking at the spectra can find the full set of plots here (more will be added as I work): https://ldas-jobs.ligo-wa.caltech.edu/~ansel.neunzert/iss_channels_combs/ .