Displaying report 1-1 of 1.
Reports until 17:53, Thursday 30 May 2024
H1 ISC (ISC)
corey.gray@LIGO.ORG - posted 17:53, Thursday 30 May 2024 (78151)
SDF Diffs: LSC & LSC AUX

LSC's SDF Diff for MICH Feed Foward gain change (0.97 to 1.00) was confirmed by Sheila and accepted.  (1st attachement)

LSCAUX's SDF Diff for LSC LOCKIN_1_Freq (& TRamp) were a mystery to Sheila, but since the amplitude was 0 for this, they were ACCEPTED.  (2nd attachment)

Images attached to this report