Displaying report 1-1 of 1.
Reports until 11:17, Saturday 01 June 2024
H1 PSL
oli.patane@LIGO.ORG - posted 11:17, Saturday 01 June 2024 (78174)
PSL Weekly Status Report - FAMIS

Closes FAMIS#26246, last checked 78062

Everything looking good besides the known high PMC refl


Laser Status:
    NPRO output power is 1.817W (nominal ~2W)
    AMP1 output power is 67.04W (nominal ~70W)
    AMP2 output power is 137.9W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 4 days, 0 hr 2 minutes
    Reflected power = 21.04W
    Transmitted power = 106.6W
    PowerSum = 127.6W

FSS:
    It has been locked for 0 days 4 hr and 43 min
    TPD[V] = 0.8871V

ISS:
    The diffracted power is around 2.3%
    Last saturation event was 0 days 4 hours and 43 minutes ago


Possible Issues:
    PMC reflected power is high