Closes FAMIS#26246, last checked 78062
Everything looking good besides the known high PMC refl
Laser Status:
NPRO output power is 1.817W (nominal ~2W)
AMP1 output power is 67.04W (nominal ~70W)
AMP2 output power is 137.9W (nominal 135-140W)
NPRO watchdog is GREEN
AMP1 watchdog is GREEN
AMP2 watchdog is GREEN
PDWD watchdog is GREEN
PMC:
It has been locked 4 days, 0 hr 2 minutes
Reflected power = 21.04W
Transmitted power = 106.6W
PowerSum = 127.6W
FSS:
It has been locked for 0 days 4 hr and 43 min
TPD[V] = 0.8871V
ISS:
The diffracted power is around 2.3%
Last saturation event was 0 days 4 hours and 43 minutes ago
Possible Issues:
PMC reflected power is high