naoki.aritomi@LIGO.ORG - posted 14:26, Wednesday 05 June 2024 (78262)
FC backscatter noise

Naoki, Sheila

To estimate the FC backscatter noise, we excited the FC IR error signal. The attached figure shows the FC IR error signal and DARM with (red)/without (blue) exciation. Although the FC IR error signal is excited by a factor of more than 30 between 10-100 Hz, the excess noise in DARM is small so the FC backscatter noise should be much smaller than DARM.