Displaying report 1-1 of 1.
Reports until 07:53, Friday 07 June 2024
H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 07:53, Friday 07 June 2024 (78300)
PSL Status Report (FAMIS #26249)

For FAMIS 26249:
Laser Status:
    NPRO output power is 1.81W (nominal ~2W)
    AMP1 output power is 66.81W (nominal ~70W)
    AMP2 output power is 137.4W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 9 days, 20 hr 40 minutes
    Reflected power = 20.94W
    Transmitted power = 106.2W
    PowerSum = 127.2W

FSS:
    It has been locked for 0 days 10 hr and 48 min
    TPD[V] = 0.8227V

ISS:
    The diffracted power is around 2.5%
    Last saturation event was 0 days 10 hours and 48 minutes ago
Possible Issues:
    PMC reflected power is high