TITLE: 06/10 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Commissioning
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 15mph Gusts, 11mph 5min avg
Primary useism: 0.05 μm/s
Secondary useism: 0.16 μm/s
QUICK SUMMARY:
Reverted to 1402011129 which is just after initial alignment.
lost lock again a number of times trying to get back to LOWNOISE_LENGTH_CONTROL
Started at line 5008 entering lines of code into guardian -i ISC_LOCK shell terminal
Lost lock @ Transition_From_ETMX after entering line 5092 from ISC_LOCK
ezca.get_LIGOFilter('SUS-ETMX_L3_LOCK_L').ramp_gain(0, ramp_time=5, wait=False) #
Many attempts to lock DRMI later and a few Alignment touchups, we arrived at CARM to Analog where there were a number of saturatrions.
I have since reached higher lock states where I waited in LOWNOISE_COIL_DRIVERS, TRANSITION_FROM_ETMX, and LOWNOISE_LENGTH_CONTROL for a few minutes EACH after they finished.
Nuc30, the main DARM Screen is acting a fowl and is not runnign correctly agian. I tried rebooting but it refused to load the XFCE4 panel & windows manager correctly.
I have made it to OMC_WHITENING but I'm greated with the following ISC_LOCK messages:
The Violins are going down the Main culprits are EYM1, EXM8, and as per usual IYM5&6 !O.o!
2024-06-10_08:00:40.526574Z ISC_LOCK [OMC_WHITENING.run] USERMSG 0: EEEEEPP! ADC Counts for the DCPDs are too high. With whitening they would be 536240, larger than the 524288 available counts! Cannot turn on OMC whitening! Stay here and damp violins
After we make it to NLN there will be a large number of SDF changes to accept.