Reports until 14:12, Monday 10 June 2024
H1 ISC (ISC, SQZ)
jennifer.wright@LIGO.ORG - posted 14:12, Monday 10 June 2024 (78354)
DARM changes after SQZ, A2L, MICH FF tuning this morning

After the commissioning period this morning where I tuned A2L gains, Naoki tuned the squeezer, and Sheila updated the MICH FF we gained noticeably at frequencies above 60 Hz and between 18 Hz to 23 Hz.

We are noticeably worse below 12 Hz.

See attached plot.

The template is stored in /jennifer.wright/Documents/ASC/20240610_DARM_pre_post_A2L_tuning.xml

Images attached to this report