TITLE: 06/17 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Observing at 155Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Currently Observing at 160 Mpc and have been locked for over one hour. Two locklosses during my shift, but both were easy to relock from.
LOG:
23:00UTC Detector Observing and Locked for 21 hours
23:22 Kicked out of Observing due to two cameras, ASC-CAM_PIT1_INMON and ASC-CAM_YAW1_INMON glitching or restarting
- Weren't able to turn back on fully and gave the warning messages "[channel_name] is stuck! Going back to ADS"
- Referencing alog 77499, we contacted Dave and he restarted camera 26 (BS cam)
23:43 Back into Observing
01:37 Lockloss
- During relocking, COMM wasn't able to get IR high enough
- I stalled ALS_COMM and tried adjusting the COMM offset by hand, but still wasn't working
02:21 I started an initial alignment
02:43 Initial alignment done, relocking
03:27 NOMINAL_LOW_NOISE
03:29 Started running SQZ alignment (SDF)
03:38 Observing
05:28 Lockloss
05:35 Lockloss from LOCKING_ALS, started an initial alignment
06:00 Initial alignment done, starting relocking
06:43 NOMINAL_LOW_NOISE
06:45 Observing