WP 11934, restart of DMT systems for updated sensemon2 with a reflection of the channels into CDS
As per WP 11934 the dmt-runtime-config package was updated on h1dmt1 and h1dmt2 followed by a reboot at around 9:40am local time.

This was to update the calculation of sensemon2 to be based off of the cleaned data.  It is desired to have these values available in CDS, so we updated the dmt2epics IOC to grab the EFF_BNS_RANGE and EFF_RED_SHIFT values and reflected them into EPICS.  After testing that we could retrieve the data from the DMT we added the channels to the EDC and rebooted the daqd around 10:30am localtime.

The new channels are:

H1:CDS-SENSMON2_BNS_EFF_RANGE_CLEAN_MPC
H1:CDS-SENSMON2_BNS_EFF_RANGE_CLEAN_MPC_GPS
H1:CDS-SENSMON2_BNS_RED_SHIFT_CLEAN
H1:CDS-SENSMON2_BNS_RED_SHIFT_CLEAN_GPS

TJ will watch the new Sensemon2 range plot as we start to lock later today and will update the FOM display if this is working well.