Displaying report 1-1 of 1.
Reports until 11:01, Thursday 20 June 2024
H1 SQZ
camilla.compton@LIGO.ORG - posted 11:01, Thursday 20 June 2024 (78551)
FC IR OLG Measurement

Sheila, Naoki, Camilla

Ran template: sqz/h1/Templates/dtt/filter_cavity/FC_IR_OLTF.xml Last done in 74228.

If IN2/EXC had peaks > 3 we'd be worried, but everything looks fine. Plot attached.

Images attached to this report