Ran A2L P

Ran the (userapps)/isc/h1/scripts/a2l/a2l_min_multi.py script for all four quads in P. Changes below have been saved in lscparams.py


         ETMX P
Initial:  3.25
Final:    3.26
Diff:     0.01

         ETMY P
Initial:  4.39
Final:    4.35
Diff:     -0.04

         ITMX P
Initial:  -1.01
Final:    -1.0
Diff:     0.01

         ITMY P
Initial:  -0.35
Final:    -0.38
Diff:     -0.03
 