J. Freed, J. Kissel
Today we did damping loop injections on all 6 BOSEMs on the ITMY. This is a continuation of the work we did previously for ITMX.
Due to a saving error, the background measurments were taken about an hour and a half after the data was collected. Leading to the results being more difficult to interpret. We also only put the gain at 600 this time when before it was at 750.
The plots, code, and flagged frequencies are located at /ligo/home/joshua.freed/20240620/Scrpts. While the diaggui files are at /ligo/home/joshua.freed/20240620/Data