corey.gray@LIGO.ORG - posted 09:05, Friday 21 June 2024 - last comment - 11:35, Friday 21 June 2024(78568)
Back To Observing, ACCEPTED an ETMX L2L Drive Align Gain

Had an SDF Diff for "ETMX_L3_DRIVEALIGN_L2L_GAIN"  (now 187.3792660000, was 187.3792260000); looks like this change is from work yesterday (alog 78555, and also screenshot).  ACCEPTED new gain.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 11:35, Friday 21 June 2024 (78575)

OK, Sheila said it was a type in guardian for this, so reverted back to the original gain value (screenshot of what I ACCEPTED...after Sheila updated guardian).  This was for the current lock.

Images attached to this comment