Jennie, TJ
I ran TJ's script to measure and set all the A2L gains for the quads.
16:05 UTC ran script in userapps/isc/h1/scripts/a2l
python a2l_min_multi.py -a
*************************************************
RESULTS
*************************************************
ETMX P
Initial: 3.26
Final: 3.19
Diff: -0.07
ETMX Y
Initial: 4.89
Final: 4.81
Diff: -0.08
ETMY P
Initial: 4.35
Final: 4.39
Diff: 0.04
ETMY Y
Initial: 1.06
Final: 1.13
Diff: 0.07
ITMX P
Initial: -1.0
Final: -1.02
Diff: -0.02
ITMX Y
Initial: 2.8
Final: 2.73
Diff: -0.07
ITMY P
Initial: -0.38
Final: -0.41
Diff: -0.03
ITMY Y
Initial: -2.41
Final: -2.28
Diff: 0.13
16:14 UTCscript finished.
TJ added these to lscparams.py and so they were loaded when Corey re-locked after the commissioning period (around 20:50 UTC).
I accepted these in OBSERVE.snap, see attached photos.