Reports until 09:39, Tuesday 25 June 2024
H1 CDS (SUS)
erik.vonreis@LIGO.ORG - posted 09:39, Tuesday 25 June 2024 - last comment - 10:36, Tuesday 25 June 2024(78642)
LIGO 28-bit DAC installed in susex

[Erik, Marc, Dave]

h1susex now has a a LIGO 28-bit 32-channel DAC installed.

The timing card was also swapped out for a new card with firmware that's compatible with the DAC.

h1susex now boots from h1vmboot0 running models built with RCG 5.3.0, necessary to support the DAC, as opposed to the rest of the front ends which boot from h1vmboot1 running RCG 5.1.4.

The timing fanout is reporting an firmware version error on the port for h1susex  (physical port 4, medm port 3).  This is probably because the firmware on the timing card is new.  We think we can run with this error.

 

DAQ Failure

After the install, DAQ leg 0 was restarted but it only connected to h1susex.  When setting up bootserver h1vmboot0, I'd accidentally replaced the DAQ master file.  Restoring the old master file resolved the issue.

Comments related to this report
erik.vonreis@LIGO.ORG - 09:46, Tuesday 25 June 2024 (78643)

Ligo 28-bit 32-channel DAC serial number is S2400042

 

marc.pirello@LIGO.ORG - 10:36, Tuesday 25 June 2024 (78646)

LIGO Timing Card installed is S2101152 flashed with FPGA code version 1000.

LIGO DB25 to BNC Breakout box installed on LD32 port 0 (directly to the adapter board).  BNC's 1-8 attach to 2nd PEM chassis ports 1-8.