H1 SYS
sheila.dwyer@LIGO.ORG - posted 10:56, Wednesday 26 June 2024 (78667)
looking for fast shutter checks for AS_C clipping in DRMI

TJ, Sheila

The fast shutter guardian runs a check in DRMI on AS_A and AS_B, it checks that the power on those PDs are above and below thresholds, which are set by the 'SYS-MOTION_C_SHUTTER_G_TRIGGER_LOW' and 'SYS-MOTION_C_SHUTTER_G_TRIGGER_HIGH' channels.   This test was passed when we had the pressure spikes, because the beam to those diodes wasn't clipped.

TJ and I have been discussing adding an additional check to try to catch the type of problem we had in our recent pressure spikes, where there was clipping on AS_C.  The table below shows values with DRMI locked, to see if we can detect the problem before fully locking the IFO.  It seems that a check on the power on AS_C would cause false alarms, because of the variablity of DRMI build ups.  A check on the ratio of AS_C to AS_A or AS_B seems more viable, but still would probably risk false alarms.  The difference between the lowest "good" ratio for AS_C/AS_A and the highest bad ratio is only 3.5%, for AS_C/AS_B that difference is only 7%. 

  AS_C NSUM (W in HAM6) AS_A NSUM AS_ B NSUM AS_C/ AS_A AS_C/ AS_B
6/6 20:46 UTC (bad) 0.046 3908 4240 1.17e-5 1.08e-5
6/7 2:30 UTC (bad) 0.049 4162 4515 1.17e-4 1.08e-5
6/7 3:20 UTC (bad) 0.048 4145 4488 1.15e-5 1.07e-5
6/6 12:08 (good) 0.052 4240 4433 1.22e-5 1.16e-5
6/6 7:10 UTC (good) 0.0506 4098 4267 1.23e-5 1.18e-5
6/6 5:21 UTC (good) 0.053 4361 4575 1.21e-5 1.16e-5
6/6 00:56 UTC (good) 0.048 3943 4105 1.21e-5 1.17e-5
6/5 23:44 UTC (good) 0.053 4319 4513 1.23e-5 1.17e-5