Displaying report 1-1 of 1.
Reports until 11:00, Saturday 29 June 2024
H1 ISC
thomas.shaffer@LIGO.ORG - posted 11:00, Saturday 29 June 2024 (78744)
Changed TMSX Opticalign tramp from 20->2

The long ramp time was confusing me while I was trying to adjust the TMS to speed up locking, so I looked into what needed such a long ramp. I thought it was the TMS servo, but it seems to only use the TEST bank. I couldn't find another place in ISC_LOCK or the ALS guardians that specifically referenced this bank, so I changed it to 2sec like for TMSY and then accepted it in SDF safe and observe. We made it through this acquisition at 2sec so maybe we're OK.

Images attached to this report
Displaying report 1-1 of 1.