h1sush2b had timing glitch caused by h1sush2a DAC replacement

At 14:44 UTC h1sush2b suffered a timing error and had to be restarted. 

The timing error happened when work was being done in the same rack in the CER, see https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=78823.

The timing error was a "long cycle" of 50 milliseconds.

 

 

Comments related to this report
david.barker@LIGO.ORG - 11:16, Wednesday 03 July 2024 (78838)

Restart log for this morning's work:

Wed03Jul2024
LOC TIME HOSTNAME     MODEL/REBOOT
05:30:57 h1sush2a     ***REBOOT*** 
05:33:09 h1sush2a     h1iopsush2a 
06:45:01 h1sush2a     ***REBOOT***
06:47:12 h1sush2a     h1iopsush2a
07:18:01 h1sush2a     ***REBOOT***
07:20:13 h1sush2a     h1iopsush2a
07:35:51 h1sush2a     ***REBOOT***
07:38:04 h1sush2a     h1iopsush2a
07:38:17 h1sush2a     h1susmc1  
07:38:30 h1sush2a     h1susmc3 
07:38:43 h1sush2a     h1susprm 
07:38:56 h1sush2a     h1suspr3
07:59:25 h1sush2b     ***REBOOT***
08:01:07 h1sush2b     h1iopsush2b
08:01:20 h1sush2b     h1susim   
08:01:33 h1sush2b     h1sushtts