Displaying report 1-1 of 1.
Reports until 19:15, Thursday 04 July 2024
H1 General (Lockloss)
ryan.crouch@LIGO.ORG - posted 19:15, Thursday 04 July 2024 - last comment - 20:56, Thursday 04 July 2024(78870)
02:13 UTC lockloss

Lost lock from an earthquake

Comments related to this report
ryan.crouch@LIGO.ORG - 19:35, Thursday 04 July 2024 (78871)

XARM kepts giving "fiber polarization error" and is in CHANGE_POL state, neither I nor guardian can get the H1:ALS-X_FIBR_LOCK_FIBER_POLARIZATIONPERCENT below 14 using the polarization controller. I called Sheila and she suggested turning on H1:ALS-X_FIBR_LOCK_LOGIC_FORCE which fixed it!

ryan.crouch@LIGO.ORG - 20:56, Thursday 04 July 2024 (78872)

03:56 UTC Observing

Displaying report 1-1 of 1.