Displaying report 1-1 of 1.
Reports until 10:27, Friday 05 July 2024
H1 ISC
camilla.compton@LIGO.ORG - posted 10:27, Friday 05 July 2024 - last comment - 13:53, Tuesday 09 July 2024(78879)
Bruco ran for 2024/07/05 13:50UTC

Bruco ran for last night's 159MPc range (instructions from Elenna), using command below. Results here.

python -m bruco --ifo=H1 --channel=GDS-CALIB_STRAIN_CLEAN --gpsb=1404222629 --length=1000 --outfs=4096 --fres=0.1 --dir=/home/camilla.compton/public_html/brucos/GDS_CLEAN_1404222629 --top=100 --webtop=20 --plot=html --nproc=20 --xlim=7:2000 --excluded=/home/elenna.capote/bruco-excluded/lho_DARM_excluded.txt

Can see:

Comments related to this report
sheila.dwyer@LIGO.ORG - 13:53, Tuesday 09 July 2024 (78976)

There are several interesting things at around 30Hz  (and around 40Hz) in this BRUCO, which might all be related to some ground motion or accoustic noise witness. 

LVEAFLOOR accelerometer

several channels related to HAM2 motion like MASTER_H2_DRIVE.  Around 38-40 Hz BRUCO picks out lots of HAM2 channels, and seems to preffer HAM2 over any other chamber.  It might be worth doing some HAM2 injections.

This time that Camilla chose was after the PSL alignment shift, but before we moved the beam on PR2 last Friday.

Displaying report 1-1 of 1.