Monthly FAMIS Check (#26491)
T240 Centering Script Output:
Averaging Mass Centering channels for 10 [sec] ...
2024-07-05 10:59:44.259990
There are 15 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.56 [V]
ETMX T240 2 DOF Y/V = -0.401 [V]
ETMX T240 2 DOF Z/W = -0.481 [V]
ITMX T240 1 DOF X/U = -1.362 [V]
ITMX T240 1 DOF Y/V = 0.317 [V]
ITMX T240 1 DOF Z/W = 0.415 [V]
ITMX T240 3 DOF X/U = -1.42 [V]
ITMY T240 3 DOF X/U = -0.713 [V]
ITMY T240 3 DOF Z/W = -1.737 [V]
BS T240 1 DOF Y/V = -0.386 [V]
BS T240 3 DOF Y/V = -0.343 [V]
BS T240 3 DOF Z/W = -0.485 [V]
HAM8 1 DOF X/U = -0.312 [V]
HAM8 1 DOF Y/V = -0.481 [V]
HAM8 1 DOF Z/W = -0.774 [V]
All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.132 [V]
ETMX T240 1 DOF Y/V = -0.101 [V]
ETMX T240 1 DOF Z/W = -0.157 [V]
ETMX T240 3 DOF X/U = -0.098 [V]
ETMX T240 3 DOF Y/V = -0.226 [V]
ETMX T240 3 DOF Z/W = -0.091 [V]
ETMY T240 1 DOF X/U = 0.04 [V]
ETMY T240 1 DOF Y/V = 0.091 [V]
ETMY T240 1 DOF Z/W = 0.153 [V]
ETMY T240 2 DOF X/U = -0.094 [V]
ETMY T240 2 DOF Y/V = 0.158 [V]
ETMY T240 2 DOF Z/W = 0.064 [V]
ETMY T240 3 DOF X/U = 0.165 [V]
ETMY T240 3 DOF Y/V = 0.062 [V]
ETMY T240 3 DOF Z/W = 0.095 [V]
ITMX T240 2 DOF X/U = 0.122 [V]
ITMX T240 2 DOF Y/V = 0.214 [V]
ITMX T240 2 DOF Z/W = 0.203 [V]
ITMX T240 3 DOF Y/V = 0.109 [V]
ITMX T240 3 DOF Z/W = 0.118 [V]
ITMY T240 1 DOF X/U = 0.037 [V]
ITMY T240 1 DOF Y/V = 0.044 [V]
ITMY T240 1 DOF Z/W = -0.066 [V]
ITMY T240 2 DOF X/U = 0.049 [V]
ITMY T240 2 DOF Y/V = 0.193 [V]
ITMY T240 2 DOF Z/W = 0.03 [V]
ITMY T240 3 DOF Y/V = 0.023 [V]
BS T240 1 DOF X/U = -0.204 [V]
BS T240 1 DOF Z/W = 0.089 [V]
BS T240 2 DOF X/U = -0.09 [V]
BS T240 2 DOF Y/V = 0.009 [V]
BS T240 2 DOF Z/W = -0.162 [V]
BS T240 3 DOF X/U = -0.202 [V]
Assessment complete.
STS Centering Script Output:
Averaging Mass Centering channels for 10 [sec] ...
2024-07-05 11:02:32.261843
There are 2 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -4.008 [V]
STS EY DOF Z/W = 2.765 [V]
All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.507 [V]
STS A DOF Y/V = -0.728 [V]
STS A DOF Z/W = -0.647 [V]
STS B DOF X/U = 0.377 [V]
STS B DOF Y/V = 0.94 [V]
STS B DOF Z/W = -0.492 [V]
STS C DOF X/U = -0.655 [V]
STS C DOF Y/V = 0.894 [V]
STS C DOF Z/W = 0.344 [V]
STS EX DOF X/U = -0.06 [V]
STS EX DOF Y/V = 0.017 [V]
STS EX DOF Z/W = 0.087 [V]
STS EY DOF Y/V = 0.025 [V]
STS FC DOF X/U = 0.239 [V]
STS FC DOF Y/V = -1.056 [V]
STS FC DOF Z/W = 0.644 [V]
Assessment complete.