Displaying report 1-1 of 1.
Reports until 16:29, Saturday 06 July 2024
LHO General
corey.gray@LIGO.ORG - posted 16:29, Saturday 06 July 2024 (78899)
Sat DAY Ops Summary

TITLE: 07/06 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY:

H1 was locked at beginning of the shift, but had a lockloss just after 10am local.  Relocking sadly took 3hrs, but it isn't clear why it took so long, because other than trying multiple times and eventually running an alignment and continued with more locking attempts, H1 finally made it past DRMI (and then locking was mostly automatic from there), but.... within an hour one of the 1kHz violins rung up (itmx13).  I made some fairly large gain drops/increases which probably didn't help---currently Rahul is closely damping with much smaller gains.  The DARM spectrum on nuc30 is glitchy/ugly---assuming it's due to noisier violins.

Sadly, no Calibration run today.

Guardian Notes:

LOG: