corey.gray@LIGO.ORG - posted 10:43, Saturday 06 July 2024 - last comment - 13:14, Saturday 06 July 2024(78904)
Lockloss & Locking Notes

h1 just had a lockloss and green arms looked decent, but it kept hanging up with locklosses (6 so far) with the LOCKING ALS. 

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 11:26, Saturday 06 July 2024 (78905)
  • Initial Alignment was fully automated & no issues.
  • Paused at problem spots earlier (LOCKING ALS & also FIND IR---no issues.
  • DRMI immediately locked, BUT
    • lockloss at DRMI_LOCKED_CHECK_ASC
    • 2nd DRMI lock took around 4-minutes.  Held at drmi locked prep asc a few minutes & then moved to engage drmi asc....
    • lockloss as the ASC control signals were being offloaded (probably same happened for previous lock).
    • Will investigate steps of ENGAGE DRMI ASC.
corey.gray@LIGO.ORG - 13:14, Saturday 06 July 2024 (78906)

Will attempt to tweak up SRM (maybe PRM/BS) at ACQUIRE DRMI 1F to help ease ASC for DRMI.

  • SRM made no change
  • PRM pit 2-clicks positively (dropped POP18 & lockloss)

Attempt #2:  automatically taken to check mich fringes then back to drmi...

  • I took to PRMI since drmi looked bad, but then a lockloss.

Attempt #3:  Went to PRMI fine.

  • Lockloss at engage drmi asc.

Attempt #4:  DRMI ASC completed FINE this time!  (I had phoned Camilla before before this lock with fears I'd need help!  Luckily, we both watched it get past DRMI.)  

  • Went back to OBSERVING at 1:11pm (2011utc)....just as Fred was giving a tour to a high school class from Aukland New Zealand!