Sun DAY Ops Summary

TITLE: 07/07 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Aligning
INCOMING OPERATOR: TJ
SHIFT SUMMARY:

Similar shift to yesterday (except we're around 102degF!), with a 4-5hr lock and 2-3hr reacquisition (with rough locking for the first 90min). 

(Since Observing time is precious, I didn't even think of running a calibration since L1 & V1 were UP all the times I could have run a calibration.)

Robert was onsite as well as JennyW for an RRT shift.
LOG:

Comments related to this report
camilla.compton@LIGO.ORG - 08:34, Monday 08 July 2024 (78936)Lockloss

Jennie Wright points out that the 19:34 lockloss 1404416083 has the glitch we've been seeing in DARM/length in the 100's ms before the lockloss 73818 73565. Her plot attached. Ianin Morton is preaping a lockloss tag for this: issue #219.