State of H1: Observing at 157Mpc, locked for 6.5 hours.
Quiet shift so far except for another errant Picket Fence trigger to EQ mode just like ones seen last night (alog78404) at 02:42 UTC (tagging SEI).
That's about two triggers in a short time. If the false triggers are an issue, we should consider triggering on picket fence only if there's a Seismon alert.
The picket fence-only transition was commented out last weekend on the 15th by Oli. We now will only transition on picket fence signals if there is a live seismon notificaition.
Thanks Jim,
I'm back from my vacation and will resume work on the picket fence to see if we can fix these errant triggers this summer.