Ran Bruco now we' ve moved spot on PR2 (alog 78878) 2024/07/10 16:18 UTC (1404663547) from when our range was ~156MPc: Link: GDS_CLEAN_1404663547/
In last week's bruco 78879, Sheila pointed out that the LVEA accelerometers and HAM2 coherence has around 30-40Hz.
- CHARD PITCH and especially YAW - bad below 25Hz
- HAM2 - Coherence < 20Hz, 30-40Hz better than last week.
- LVEA Floor Accel XCYRO -last weeks 30-40Hz coherence mostly gone
- PRCL - better than last week, still broad coherence at 0.1 level.
- SRCL -13, 17, 20Hz coherent peaks
- MICH - 20Hz coherent peak