Further potential fast shutter checks with the AS_ pds but at Prep for DC

Following up from alog78667 where Sheila compared AS_{A,B,C} powers and some of their ratios during our bad alignments and our good ones, I've done the same thing but at the ISC_LOCK state of Prep_DC_Readout_Transition (500). Just like before, the difference between the lowest good AS_C/AS_A ratio and the highest bad ratio is still pretty low. About the same actually.

  AS_C NSUM (W in HAM6) AS_A NSUM AS_ B NSUM AS_C/ AS_A AS_C/ AS_B
6/6 20:53 UTC (bad) 0.0724 6156 6670 1.176e-5 1.086e-5
6/7 2:42 UTC (bad) 0.0759 6544 7063 1.160e-5 1.075e-5
6/7 3:29 UTC (bad) 0.0763 6566 7082 1.162e-5 1.077e-5
6/6 12:19 (good) 0.0862 7109 7335 1.213e-5 1.175e-5
6/6 7:20 UTC (good) 0.0793 6540 6792 1.213e-5 1.168e-5
6/6 01:11 UTC (good) 0.0797 6569 6781 1.213e-5 1.175e-5
6/5 10:59 UTC (good) 0.0765 6292 6547 1.216e-5 1.169e-5
7/10 08:15 UTC (good) 0.0790 6392 6771 1.236e-5 1.167e-5
7/9 20:51 UTC (good but with lower range) 0.0789 6383 6754 1.236e-5 1.168e-5