New settings for damping rung up violin mode ITMY mode 05 and 06

The following settings seems to be working for now and I will commit it in the lscparams after a couple of IFO lock stretches.

New settings (ITMY05/06):- FM5 FM6 FM7 FM10 Gain +0.01 (new phase -90 degree), might increase the gain later on depending upon how slow the damping is.

Nominal settings (ITMY05/06): FM6 FM8 FM10 Gain +0.02 (phase -30deg)

Given below are settings I tried this morning and it did not work,

1. no phase, 0.01 gain - increase
2. -30 phase, -0.01 gain - increase
3. +30 phase, 0.01 gain - increase
4. -30 phase, 0.01 gain - IY05 decreasing (both filters) IY06 increasing (both filters)
5. -60 phase, 0.01 gain - IY05 decreasing (both filters) IY06 increasing (only in narrow filter)

---

After talking to TJ, I have set the gain to zero on lscparams and saved it but not loaded it since we are OBSERVING. Will load it once there is a target or opportunity.

Images attached to this report
Comments related to this report
rahul.kumar@LIGO.ORG - 16:30, Wednesday 10 July 2024 (79011)

DARM spectra attached below shows that both the modes are slowly decreasing, next I will try and bump up the gain to 0.02.

Images attached to this comment
rahul.kumar@LIGO.ORG - 15:35, Thursday 11 July 2024 (79043)SUS

ITMY 05/06 - FM5 FM6 FM7 FM10 Gain +0.02 has been saved in lscparams and violin mode Guardian has been loaded for the next lock.