Reports until 08:47, Friday 12 July 2024
H1 ISC
ryan.crouch@LIGO.ORG - posted 08:47, Friday 12 July 2024 - last comment - 09:03, Friday 12 July 2024(79066)
Ran A2L P & Y

Ran the (userapps)/isc/h1/scripts/a2l/a2l_min_multi.py script for all four quads in both P and Y to try and help our range. Minimal improvements, this was done in tandem with the SQZ scans which gained us about 2 Mpc.

ETMX P
Initial:  3.12
Final:    3.09
Diff:     -0.03

          ETMX Y
Initial:  4.79
Final:    4.81
Diff:     0.02

          ETMY P
Initial:  4.48
Final:    4.49
Diff:     0.01

          ETMY Y
Initial:  1.13
Final:    1.26
Diff:     0.13

          ITMX P
Initial:  -1.07
Final:    -1.02
Diff:     0.05

          ITMX Y
Initial:  2.72
Final:    2.79
Diff:     0.07

          ITMY P
Initial:  -0.47
Final:    -0.43
Diff:     0.04

          ITMY Y
Initial:  -2.3
Final:    -2.36
Diff:     -0.06

Comments related to this report
ryan.crouch@LIGO.ORG - 09:03, Friday 12 July 2024 (79068)

SDFed

Images attached to this comment