Moved SR3 with SR2 following to find spots with good AS port power

To help characterize the recent issues we've seen with IFO alignment that are familiar to the output change in late April, I moved SR3 in 10W single-bounce configuration with the SRC2 ASC loop on so that SR2 would follow (ALIGN_IFO's SR2_ALIGN state), much like in alog77694. I moved SR3 far enough in each direction (+/- pitch and yaw) to bring the ASC-AS_C_NSUM signal back up to our target value of 0.022, which I was successful doing in every direction except -Y, where I could only bring AS_C up to 0.018. In the three directions where I was successful, the beam spot on the AS AIR camera looked much more like the clear circle we're used to seeing and less like the upside-down apostrophe we have now.

It seems that our old output spot (starting place in TJ's alog) is still bad (-Y direction with SR3 from current place) since that was the only direction where I couldn't get the AS_C power back up.

Slider values of SR3 after each move:

  Start +P move -P move +Y move -Y move
SR3 P slider 438.7 651.1 138.7 438.7 438.7
SR3 Y slider 122.2 122.2 122.2 322.2 -167.8

Attachment 1 is the starting AS AIR camera image (and our current spot), attachment 2 is after the +P move, attachment 3 is after the -P move, and attachment 4 is after the +Y move.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 15:15, Monday 15 July 2024 (79135)
 
Before
+P move
-P move
+Y move
-Y move
Time
1404952764
2024/07/14 00:39:06 UTC
1404955465
2024/07/14 01:24:07 UTC
1404958133
2024/07/14 02:08:35 UTC
1404959716
2024/07/14 02:34:58 UTC
1404963518
2024/07/14 03:38:20 UTC
H1:SUS-SR3_M1_OPTICALIGN_P_OFFSET
438.7
651.1
138.7
438.7
438.7
H1:SUS-SR3_M1_OPTICALIGN_Y_OFFSET
438.7
122.2
122.2
322.2
-167.8
H1:SUS-SRM_M1_DAMP_P_INMON
-1033.7
-1035.2
-1036.3
-1036.1
-1037.1
H1:SUS-SRM_M1_DAMP_Y_INMON 
913.7
914.0
914.1
914.1
914.2
H1:SUS-SR2_M1_DAMP_P_INMON
597.7
-871.6
2660.2
614.7
566.2
H1:SUS-SR2_M1_DAMP_Y_INMON 
1125.3
1179.9
1069.3
1878.8
-72.4
H1:SUS-SR3_M1_DAMP_P_INMON 
-290.2
-57.7
-619.4
-297.9
-279.1
H1:SUS-SR3_M1_DAMP_Y_INMON
-411.0
-425.2
-390.4
-256.9
-633.7

Here are the OSEM values, so that Alena can cotinine her 78268 analysis of the OFI beam spot position.

sheila.dwyer@LIGO.ORG - 21:14, Monday 15 July 2024 (79154)

Adding a screenshot of sliders for the -P alignment above, after initial alignment.

Images attached to this comment