ryan.crouch@LIGO.ORG - posted 09:52, Friday 12 July 2024 - last comment - 09:05, Monday 15 July 2024(79073)
Lockloss at 16:44 UTC

16:44 UTC lockloss. PRCL was oscillating at about ~3.6 Hz.

Comments related to this report
ryan.crouch@LIGO.ORG - 12:55, Friday 12 July 2024 (79078)

We've lost it at PREP_DC_READOUT twice in a row, during different points of the OMC locking process. Lockloss tool tags ADS_EXCURSION

camilla.compton@LIGO.ORG - 09:05, Monday 15 July 2024 (79111)

We turned on a PRCL FF the day before: 79035. But this 3.6Hz PRCL wobble is normal, it was constant throughout the lock plot and locks before the feedforward was installed (example).

This lockloss looked very normal, AS_A then IMC loosing lock, as usual, plot.