Displaying report 1-1 of 1.
Reports until 12:25, Monday 30 September 2013
H1 CDS
cyrus.reed@LIGO.ORG - posted 12:25, Monday 30 September 2013 (7913)
sw-msr-h1fe Reboot - Switch Syslog Updates
sw-msr-h1fe decided to reboot itself today at 10:45AM, the cause is unknown but most likely related to the power problems earlier in the morning.  When I went looking for syslogs for possible clues, I realized that none of the Netgear switches had remote sysloging enabled, so I took the time to make that configuration change on all the switches, as well as the Fujitsu DAQ broadcast switch.  The installed Cisco switches and APs already had syslog logging enabled.  There is no guarantee that having syslog messages will give any indication of what caused a problem (in this case reboot), but it provides more information than none at all...
Displaying report 1-1 of 1.