Displaying report 1-1 of 1.
Reports until 15:43, Monday 15 July 2024
H1 ISC
sheila.dwyer@LIGO.ORG - posted 15:43, Monday 15 July 2024 - last comment - 20:58, Monday 15 July 2024(79140)
moved SR3, relocking after fast shutter test

Sheila, Keita, Ryan Short, Camilla and TJ

Part way through initial alignment, we stopped and moved SR3 towards the positive yaw spot from 79103, and used the SR2 osem values from that time.  A small manul adjustment of AS_C was needed, otherwise initial alingment was uneventful.

With DRMI locked, we ran the fast shutter test that Keita and Ryan S have both looked at.

We also looked at the ratios of AS PDs  to compare to   78667, they are most similar to the good times in that alog. After these checks we have decided to try locking.

Comments related to this report
keita.kawabe@LIGO.ORG - 15:55, Monday 15 July 2024 (79141)

Fast shutter behavior is attached. It's working fine, but the throughput to HAM6 is ~14% down compared with before.

Before the shutter was closed, ASC-AS_A_DC_NSUM was ~3.7k counts, and  ~0.75 counts after (fractional number because of decimation to 2k). That's about 200ppm.

However, it used to be ~4.3k and 1cts on one of the "happy" plots alog 79131, 3.7k/4.3k~0.86, so the throughput to HAM6 seems to be ~14% lower than before.

Images attached to this comment
keita.kawabe@LIGO.ORG - 16:33, Monday 15 July 2024 (79147)

IFO lost lock even before going DC and we had another FS test forced by the guardian, and it didn't fail, but the throughput is even worse.

A_DC_SUM=3.4k when the shutter was open, Closed/Open ratio is about 1000ppm, and a tiny part of the beam is being missed by the shutter (attached). Note that I'm NOT eyeballing the "open" Y cursor in log scale, I set it while in linear Y scale but changed it to log to show that the power after the shutter was closed seems to be measurably larger than it should be.

Maybe this is going on because of tiny alignment differences from lock to lock, but anyway this doesn't look to be the place we want.

Images attached to this comment
sheila.dwyer@LIGO.ORG - 20:58, Monday 15 July 2024 (79153)

I think the reason that the power levels were low on AS_A and AS_B in the DRMI lock mentioned above was because DRMI was poorly aligned, not due to excess output arm losses.

Last good lock: DRMI locked, POP18 NORM was 65.3, POP90 NORM was 9.7,  AS_A DC 4173 cnts, AS B DC was 4395 and AS_C was 0.0517 (Watts into HAM6).

In today's earlier DRMI lock, POP18 NORM was 55.35 (15% lower than the good lock) POP90 NORM was 12.27 counts (30% higher).  I think this indicates that DRMI was poorly aligned in this earlier lock, not necessarily that it was a bad spot through the OFI.

Displaying report 1-1 of 1.