Reports until 17:03, Monday 15 July 2024
H1 ISC (ISC, SUS)
marc.pirello@LIGO.ORG - posted 17:03, Monday 15 July 2024 - last comment - 13:19, Tuesday 16 July 2024(79151)
Briefly tested LD32 DAC SUS-EX

Today we conducted a brief test on the SUS-EX ESD DAC vs the SUS-EX LD32 DAC, both driving the PEM AA chassis at end X per WP11976.  This testing was cut short due to relocking attempts.  We changed the cable to the PEM output ~1:10pm PST, and replaced the cable back to its original position at ~2:15pm PST.  We are still looking at the results of this testing.

F. Clara, R. McCarthy, M. Pirello, D. Sigg

Comments related to this report
daniel.sigg@LIGO.ORG - 13:19, Tuesday 16 July 2024 (79173)

We compared the output of the 20-bit DAC with the LIGO DAC. There is delay of about 90us. More than we would have expected. Decimation filter delay for a ~30kHz cut-off is about 14us. The filters are getting processed and sent to the DAC at a rate of 1MHz. So, maybe ~1-3us processing delay.