Displaying report 1-1 of 1.
Reports until 15:43, Wednesday 17 July 2024
H1 ISC
camilla.compton@LIGO.ORG - posted 15:43, Wednesday 17 July 2024 (79193)
Finding SQZ and IFO single bounce alignment values from early April and June

Sheila, Jennie, Camilla

Now Jim has locked HAM5/6 HEPI and isolated ISI's (to be similar to when vented and locked), we recreated the IFO single bounce and SQZ alignments onto AS_C for the recent bad OFI spot and the April OFI bad spot. Used template/ligo/home/camilla.compton/Desktop/SRC_OMC_align.yaml

This should simplify setting alignment references once vented.

July bad OFI spot (alignment used May-July):

April bad OFI spot (alignment used pre-April):

Images attached to this report