Displaying report 1-1 of 1.
Reports until 15:30, Wednesday 17 July 2024
H1 CDS
david.barker@LIGO.ORG - posted 15:30, Wednesday 17 July 2024 - last comment - 18:45, Wednesday 17 July 2024(79197)
BSC2 cold cathode gauge removed from alarms while it is off for the vent

Travis requested that the cell phone alarms for BSC2 vacuum gauge be turned off for the duration of the vent. I have removed the PT120 pressure and error channels from the alarms system and restarted the systemd alarms.service on cdslogin.

Channels removed are:

H0:VAC-LY_Y1_PT120B_PRESS_TORR

H0:VAC-LY_Y1_PT120B_PRESS_TORR_ERROR

Comments related to this report
david.barker@LIGO.ORG - 18:45, Wednesday 17 July 2024 (79203)

Ditto for HAM6

H0:VAC-LX_Y0_PT110_MOD1_PRESS_TORR

H0:VAC-LX_Y0_PT110_MOD1_PRESS_TORR_ERROR

Displaying report 1-1 of 1.