Displaying report 1-1 of 1.
Reports until 15:56, Wednesday 17 July 2024
H1 SUS (SUS)
corey.gray@LIGO.ORG - posted 15:56, Wednesday 17 July 2024 - last comment - 10:37, Thursday 18 July 2024(79189)
ZM6, OM1, OM2 (+OM3 by RyanC, +OMC by Rahul) Transfer Functions Are COMPLETED (In Prep For Vent)

SUMMARY:  Transfer Functions COMPLETED for ZM6, OM1, & OM2.  Leaving in DAMPED guardian state for vent.  Will post matlab plots in a comment to this alog later.

Joined team of others (Ibrahim, Jeff, Rahul, RyanC) in getting SUSpension transfer functions in preparation for upcoming vent.  We split up the work amongst us.  I took on ZM6, OM1 and OM2

7/18/24 Update NOTE:  OM3 measured by Ryan C, OMC measured by Rahul.  Their results are posted in a comments below!

Instructions for this work is at:  https://awiki.ligo-wa.caltech.edu/wiki/Suspensions/OpsManual/TFs/DTT

For TODAY, this is what I did:

Here are the locations of the files noted above:

Will leave all of these SUSpensions in their DAMPING  guardian state (vs ALIGNED).

Comments related to this report
ryan.crouch@LIGO.ORG - 16:21, Wednesday 17 July 2024 (79199)

I ran the first analysis code for the OMs.

Non-image files attached to this comment
corey.gray@LIGO.ORG - 09:03, Thursday 18 July 2024 (79208)

Attached are the Matlab-generated plots for ZM6 (with measurements I ran yesterday).

(Ryan already made the plots for OM1 & OM2 which I measured yesterday--Thanks!)

I should note this was my first time running through this procedure for taking SUS transfer functions.  I had a few issues which came up (mainly svn-related), but got through some of this yesterday with Jeff's help, and Erik helped me this morning with other svn issues, but for these issues, I opted to not run an SVN update since there was a note for a "conflict".  So I skipped the svn steps for plotting.

Non-image files attached to this comment
anthony.sanchez@LIGO.ORG - 09:58, Thursday 18 July 2024 (79212)

The Latest H1SUSZM6_M1_ALL_TFs.pdf  is now availible
If you want to know where this lives on the CDS machines it can be found here: 
/ligo/svncommon/SusSVN/sus/trunk/HXDS/H1/ZM6/SAGM1/Results

Non-image files attached to this comment
rahul.kumar@LIGO.ORG - 10:37, Thursday 18 July 2024 (79215)SUS

I have taken the in-vacuum measurements for OMC (HAM6) and they look great - see screenshots attached below.

Images attached to this comment
Displaying report 1-1 of 1.