Displaying report 1-1 of 1.
Reports until 11:45, Tuesday 23 July 2024
H1 SUS (SUS)
ryan.crouch@LIGO.ORG - posted 11:45, Tuesday 23 July 2024 (79283)
ETM OPLEV charge measurement

I took the OPLEV charge measurement for the both the ETMs this morning as they were free. As I started I noted that ETMX had an FPU error (floating point unit), and during the measurement ETMY had lots of overflows, all stemming from H1:FEC-98_DAC_OUTPUT_3_3 (ETMX did not have any overflows).

To center the OPLEVs I had to do the following slider moves

ETMX sliders: P -42.7 to -57.8, Y -147.7 to -131.3

ETMX's charge appears to be increasing and high, its at or above 50V on all quads/DOF.

ETMY sliders: P 140.1 to 170.8, Y -162.8 to -149.0

ETMY's charge seems stable and low, hovering around 0-50 V on all the quads.

After I was finished I restored the sliders and re-misaligned the ETMs as they were when I found them.

 

Images attached to this report