OFI KTP Wedge Reinstalled and alignment checked

Sheila, Keita, Betsy, Camilla

New KTP crystal reinstalled, alignment checked,  99.96% transmission and 0.17% rejected. We don't plan to adjust the KPT further and will next remove the FS.
 
Sheila and I measured the distance between KPT holder with the new crystal (79326) and irises in the optics lab (890mm to left far iris and 880mm to right far iris) and then moved it to HAM5.
We checked the OFI suspension was supported using ther dog camps and finger lockers as in 79315 and then placed the KPT assembly with the teflon barrier in place.
There's not much wiggle room but we pushed the KTP assembly as far toward +Y as we could and then tightened it down.
Then let the OFI suspension hang freely.
 
We checked SRM osems were good.
Keita and Sheila could see the retroflected beam on the iris after the aux laser. The beam was also hitting the OM1 iris, maybe 0.5mm off in yaw.

In the last power measurements in 79313 we were loosing 25% through OFI and another 15% from lost through incorrect polarization through the TFP.

Today's measurements:

From the mean of these measurements Sheila and Louis calculated the rejected ratio (power sent to ZM6) is 0.17 ± 0.002%. The transmission through to HAM6 is 99.96 ± 1.45%. The sum of these is 100.13%, which is within the margin off error.

Comments related to this report
camilla.compton@LIGO.ORG - 12:35, Monday 29 July 2024 (79349)

Attached is a .txt version of the .py file Sheila did this calculation in.

Non-image files attached to this comment
camilla.compton@LIGO.ORG - 14:23, Wednesday 31 July 2024 (79384)

We realized that we overestimated the errors here so the transmission through to HAM6 is 99.96 ± 0.84%. Rejected ratio (power sent to ZM6) is 0.17 ± 0.001%. Updated code attached and more recent measurements (with swapped FS) in 79383

Non-image files attached to this comment