Reports until 15:43, Thursday 01 August 2024
H1 SUS (CDS, SUS)
rahul.kumar@LIGO.ORG - posted 15:43, Thursday 01 August 2024 - last comment - 10:01, Friday 02 August 2024(79419)
HAM5 SR3 Triple Top Coil Driver replaced due to M1 stage CD state binary issue

Fil, RyanC, Rahul

We have replaced the triple top coil driver for SUS SR3 after finding  binary issues with T1 channel on the M1 stage - see pic attached. T1 LP filter was not switching OFF and was stuck at ON. We looked at the SUS HAM5-6 system wiring diagram on D1002740 and found out that the chassis is at slot41, Rack C7. At first Fil tried re-setting the chassis (binary chasiss was power cycled) and then replaced cable no 44 and 45 (page 1 0f D1002740), which didn't give us the desired results, i.e T1 was still stuck at On, while channel LF and RT (Test/COIL) turned Red at the AI chassis.

Fil then decided to replace the Top Triple coil drive and this fixed the issue. Given below are the s/n of the old and new coil driver,

New - S1001082

Old - S1100192

I have added the above information on the e-traveler.

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 16:32, Thursday 01 August 2024 (79422)SUS

Comparison of the TFs for V, before and after the chassis swap.

Images attached to this comment
rahul.kumar@LIGO.ORG - 10:01, Friday 02 August 2024 (79431)CDS, SUS

FRS ticket 31753 filed and closed.